How to install a DC geared motor

The number of clicks:   Update time: 20/08/28 11:07:08 Source:www.worm-drive-motor.xyz关闭share it:
  DC gear motors are widely used in various industries, so they are loved by many users.Many people use or buy equipment and feel confused during the installation process.Therefore, the editor introduced the installation method of the equipment in detail.
  (1) When installing a DC geared motor, pay attention to the position of the transmission to be aligned, and the error should not be greater than the use compensation of the coupling used.Good alignment can prolong the service life and obtain the ideal transmission efficiency.
  (2) When installing transmission parts on the output shaft, it is not allowed to hit with a hammer.The assembly fixture and the internal thread of the shaft end are usually pressed into the transmission parts with bolts, otherwise the internal parts of the DC geared motor may be damaged.It is not recommended to use rigid fixed couplings.Improper installation of this type of coupling will cause external loads, leading to early damage to the bearing, and even breakage of the output shaft.
  (3) The DC geared motor should be firmly installed on a stable foundation or base, the oil in the drain tank should be drained, and the cooling air circulation should be smooth.The foundation is unreliable, vibration and noise will be generated during operation, and bearings and gears will be damaged.When the transmission coupling has protrusions or gears and the sprocket is used in the transmission, consider installing a protective device.When the output bearing is subjected to a large radial load, it should be selected.
  (4) According to the designated installation device, ensure that the operator can easily access the oil standard, exhaust plug and oil drain plug.After the installation is in place, check the accuracy of the installation position and the reliability of the pressing of each fastener in turn.After installation, it should be able to rotate flexibly.The DC reducer is lubricated by splashing oil pool.Before operation, the user should remove the vent plug and replace it with the vent plug.According to different installation positions, open the screw of the oil level plug and check the height of the oil pipe.Add oil from the oil level plug until the oil overflows from the screw hole of the oil level plug.After screwing on the oil level plug and ensuring that it is correct, a no-load test run of no less than 2 hours can be carried out.The operation should be stable and free of shock, vibration, noise and oil leakage.If an abnormality is found, it should be eliminated in time.After a period of time, check the oil level again to prevent possible leakage from the casing.If the ambient temperature is too high or too low, you can replace the lubricating oil.
  According to the editor's introduction to the use and installation of DC geared motors, this article describes in detail.In the future operation and use, it is recommended that you read the instructions and precautions carefully before use to ensure the normal use of the equipment.
contactwe If you have any questions, you are welcome to inquire at any time